8.5 m³/h automatic chemical dosing for industrial cooling water — Brazil

Proposed automatic dosing skid for pH and nitrite control in industrial recirculating cooling water.

Project Background

The client-supplied design basis includes a 5 m³ effective process-water tank, 8.5 m³/h circulation, inlet pH of 11–12, low alkalinity and hardness, and target pH of 8–11 and nitrite of 1,500 ppm. The proposed skid uses sulfuric acid and corrosion inhibitor with online analysis and Modbus TCP control, subject to confirmation of water chemistry, dosing properties, and site constraints.

Our Solution

The proposed solution is an automatic chemical-dosing skid comprising a 8.5 m³/h recirculation duty, an effective process-water tank, two duty/standby metering pumps, sulfuric-acid and corrosion-inhibitor dosing lines, pulse dampening, back-pressure valves, static mixing, and return-line injection. pH is measured continuously and used to trim acid dosing, while nitrite analysis provides a second controlled variable for inhibitor dosing or related treatment adjustment. A PLC/HMI manages interlocks, alarms, pump rotation, level control, and Modbus TCP communications. Bunding, secondary containment, compatible tubing, and an emergency spill response arrangement are proposed for chemical handling. Any sludge or concentrate is not generated in this closed-loop application; spent chemical solution is retained for controlled disposal under the confirmed SDS and local requirements. Final pump sizing, materials, control strategy, and certification will be revised after the outstanding client data are received.

What We Asked First

Please confirm the required circulation basis, sulfuric acid concentration and SDS, corrosion-inhibitor composition and SDS, normal pH setpoint, nitrite concentration basis, piping backpressure, ambient conditions, hazardous-area classification, applicable certifications, and DCS interface permissions.

Proposed Process Train

  1. 1Client process-water storage and equalisation
  2. 2Recirculation from the industrial cooling-water circuit
  3. 3Controlled sulfuric acid dosing for pH adjustment
  4. 4Controlled corrosion-inhibitor dosing
  5. 5Return-line blending and static mixing
  6. 6Inline pH and nitrite analysis with PLC/HMI feedback
  7. 7Off-line analysis, calibration, and safe residual handling

For Similar Projects

Prepare the process-water analysis, complete chemical SDS and dosing curves, recirculation and backpressure data, control requirements, site photographs, hazardous-area classification, and interface drawings for detailed design review.

Ref. A-014. Client identity is withheld under our client-confidentiality policy. Capacity is shown as a capacity class (design value rounded up to the next 5 at its second significant digit).

How We Deliver

Projects of this type are delivered in the nine stages below. Installation, commissioning and other on-site stages follow each contract's scope. Every stage within our scope produces a written record that we keep on file.

  1. 1 Design basis confirmationAverage and peak flow, influent or gas data, discharge or reuse target Record producedDesign basis sheet
  2. 2 Process & mechanical designProcess calculations, equipment selection, layout and piping Record producedCalculation book, P&ID, general arrangement
  3. 3 Manufacturing & quality controlMaterial and in-process inspection of the main equipment Record producedMaterial & QC records
  4. 4 Factory acceptance test (FAT)Trial run against the design parameters before dispatch Record producedFAT record
  5. 5 Packing & dispatchPacked, marked and shipped against the equipment list Record producedPacking list
  6. 6 Installation or supervisionPer contract scope Record producedInstallation record
  7. 7 CommissioningStart-up, parameter tuning and interlocks Record producedCommissioning log
  8. 8 Performance verificationEffluent or emission checked against the design basis Record producedPerformance test record
  9. 9 Training, handover & after-salesOperator training, document handover, after-sales support Record producedO&M manual, training record

Planning a similar project? Start with these six parameters

  1. FlowDaily average and peak (m³/day and m³/h)
  2. Influent qualityCOD, BOD₅, TSS, pH and anything unusual
  3. Discharge targetThe standard you must meet, or the reuse purpose
  4. Operating hoursContinuous or batch; seasonal changes
  5. Site & civil scopeFootprint, power supply, who builds the tanks
  6. Project stageBudgeting, tender, or ready to order

Send your parameters — initial process recommendation within 24 hours

Frequently Asked Questions

This project is listed in the 8.5 m³/h capacity class: the design value rounded up to the next 5 at its second significant digit. Exact design values are not published.
The process train under assessment is: Client process-water storage and equalisation → Recirculation from the industrial cooling-water circuit → Controlled sulfuric acid dosing for pH adjustment → Controlled corrosion-inhibitor dosing → Return-line blending and static mixing → Inline pH and nitrite analysis with PLC/HMI feedback → Off-line analysis, calibration, and safe residual handling.
Yes. Send us your daily and peak flow, influent quality, discharge or reuse target, operating hours and site constraints, and our engineers will reply with an initial process recommendation within 24 hours.

Planning a similar project?

Share your flow, influent quality and discharge target — our engineers respond within 24 hours.