Proposed containerised wastewater and RO water treatment systems

Proposed treatment for a multi-unit camp comprising domestic sewage treatment and filtered RO drinking-water production, subject to source-water testing.

Project Background

The client-supplied design basis comprises four independent containerised units at one camp, including two sewage treatment systems and two RO water-treatment systems. Sewage flows and potable-water demand differ between units. Influent characteristics, discharge criteria, source-water composition, fluoride and microbial limits, operating hours, storage, power and container requirements remain to be confirmed before final process selection.

Our Solution

A modular sewage train is proposed using screening, equalisation, biological treatment, solids separation and disinfection, with MBR selected where clarified effluent quality or footprint is critical and MBBR where simpler operation is preferred. Dewatered sludge would be contained for periodic removal. The supply-water train would use multimedia and cartridge filtration, RO and final disinfection to control dissolved salts and fluoride while limiting microbial exposure. RO concentrate would be collected for controlled disposal or reviewed reuse after characterisation. Final equipment, recovery, disinfection methods and performance criteria would follow confirmation of wastewater composition, raw-water quality, applicable standards, operating conditions and client data.

What We Asked First

Please confirm the number, location and duty of each unit; wastewater sources; discharge destination and applicable limits; source-water analysis; required fluoride and microbial standards; operating hours; storage; power; container arrangement; scope; and programme.

Proposed Process Train

  1. 1Coarse screening and flow equalisation
  2. 2Biological treatment with MBBR or MBR
  3. 3Clarification or membrane separation
  4. 4Disinfection and treated-water storage
  5. 5Sludge thickening and dewatering
  6. 6Pretreatment with media filtration and cartridge filtration
  7. 7RO desalination
  8. 8Post-treatment disinfection and storage
  9. 9Concentrate management

For Similar Projects

Prepare source-water and wastewater analyses, applicable discharge and potable-water standards, unit schedules, operating profiles, storage needs, utility arrangements, container layouts and a defined maintenance and residual-disposal plan.

Ref. A-029. Client identity is withheld under our client-confidentiality policy. Capacity is shown as a capacity class (design value rounded up to the next 5 at its second significant digit).

How We Deliver

Projects of this type are delivered in the nine stages below. Installation, commissioning and other on-site stages follow each contract's scope. Every stage within our scope produces a written record that we keep on file.

  1. 1 Design basis confirmationAverage and peak flow, influent or gas data, discharge or reuse target Record producedDesign basis sheet
  2. 2 Process & mechanical designProcess calculations, equipment selection, layout and piping Record producedCalculation book, P&ID, general arrangement
  3. 3 Manufacturing & quality controlMaterial and in-process inspection of the main equipment Record producedMaterial & QC records
  4. 4 Factory acceptance test (FAT)Trial run against the design parameters before dispatch Record producedFAT record
  5. 5 Packing & dispatchPacked, marked and shipped against the equipment list Record producedPacking list
  6. 6 Installation or supervisionPer contract scope Record producedInstallation record
  7. 7 CommissioningStart-up, parameter tuning and interlocks Record producedCommissioning log
  8. 8 Performance verificationEffluent or emission checked against the design basis Record producedPerformance test record
  9. 9 Training, handover & after-salesOperator training, document handover, after-sales support Record producedO&M manual, training record

Planning a similar project? Start with these six parameters

  1. FlowDaily average and peak (m³/day and m³/h)
  2. Influent qualityCOD, BOD₅, TSS, pH and anything unusual
  3. Discharge targetThe standard you must meet, or the reuse purpose
  4. Operating hoursContinuous or batch; seasonal changes
  5. Site & civil scopeFootprint, power supply, who builds the tanks
  6. Project stageBudgeting, tender, or ready to order

Send your parameters — initial process recommendation within 24 hours

Frequently Asked Questions

The process train under assessment is: Coarse screening and flow equalisation → Biological treatment with MBBR or MBR → Clarification or membrane separation → Disinfection and treated-water storage → Sludge thickening and dewatering → Pretreatment with media filtration and cartridge filtration → RO desalination → Post-treatment disinfection and storage → Concentrate management.
Yes. Send us your daily and peak flow, influent quality, discharge or reuse target, operating hours and site constraints, and our engineers will reply with an initial process recommendation within 24 hours.