Wastewater treatment expert: +86-181-0655-2851 Get Expert Consultation

Domestic sewage treatment system for a municipal application – Cambodia

A proposed packaged domestic sewage treatment system for client review, subject to confirmation of the design basis and receiving requirements.

Project Background

The client requires treatment of domestic sewage at a client-supplied design basis of 12–15 m³/d, with the final plant configuration to be confirmed. The proposed package includes a composite reactor, aeration and ventilation equipment, pipework, controls, access covers and inlet and outlet connections. Influent characteristics, discharge limits and the intended effluent destination remain to be provided.

Our Solution

The proposed solution is a packaged biological treatment system suitable for domestic sewage, comprising inlet screening and equalisation, anaerobic biological treatment, aerated secondary treatment, solids separation, filtration and disinfection. The composite reactor provides a compact installation footprint, while aeration and ventilation support biological treatment and the solids separator returns retained biomass to the treatment stages. Disinfection is included as a final barrier before the effluent is routed for disposal or reuse, subject to the applicable receiving requirements. Settled and excess sludge will undergo digestion and mechanical dewatering before temporary storage and authorised collection or disposal. Final process selection, equipment arrangement and treatment objectives will be confirmed after the client provides the influent data, required effluent limits, receiving destination and site information.

What We Asked First

Please confirm the applicable ten discharge parameters and their limits or specification, the receiving water or reuse purpose, whether the stated design flow applies to one complete system or the total project, and the required delivery and installation location.

Proposed Process Train

  1. 1Incoming domestic sewage screening and flow equalisation
  2. 2Anaerobic biological treatment in a composite tank
  3. 3Secondary biological treatment with aeration and settled solids separation
  4. 4Effluent filtration
  5. 5Disinfection
  6. 6Treated effluent collection and disposal or reuse
  7. 7Digestion and dewatering of accumulated sludge
  8. 8Storage and periodic collection of dewatered sludge

For Similar Projects

Prepare the effluent limits, reuse or discharge destination, representative influent samples and site information so the treatment train, civil works, installation scope and sludge handling route can be finalised.

Ref. A-036. Client identity is withheld under our client-confidentiality policy. Capacity is shown as a capacity class (design value rounded up to the next 5 at its second significant digit).

How We Deliver

Projects of this type are delivered in the nine stages below. Installation, commissioning and other on-site stages follow each contract's scope. Every stage within our scope produces a written record that we keep on file.

  1. 1 Design basis confirmationAverage and peak flow, influent or gas data, discharge or reuse target Record producedDesign basis sheet
  2. 2 Process & mechanical designProcess calculations, equipment selection, layout and piping Record producedCalculation book, P&ID, general arrangement
  3. 3 Manufacturing & quality controlMaterial and in-process inspection of the main equipment Record producedMaterial & QC records
  4. 4 Factory acceptance test (FAT)Trial run against the design parameters before dispatch Record producedFAT record
  5. 5 Packing & dispatchPacked, marked and shipped against the equipment list Record producedPacking list
  6. 6 Installation or supervisionPer contract scope Record producedInstallation record
  7. 7 CommissioningStart-up, parameter tuning and interlocks Record producedCommissioning log
  8. 8 Performance verificationEffluent or emission checked against the design basis Record producedPerformance test record
  9. 9 Training, handover & after-salesOperator training, document handover, after-sales support Record producedO&M manual, training record

Planning a similar project? Start with these six parameters

  1. FlowDaily average and peak (m³/day and m³/h)
  2. Influent qualityCOD, BOD₅, TSS, pH and anything unusual
  3. Discharge targetThe standard you must meet, or the reuse purpose
  4. Operating hoursContinuous or batch; seasonal changes
  5. Site & civil scopeFootprint, power supply, who builds the tanks
  6. Project stageBudgeting, tender, or ready to order

Send your parameters — initial process recommendation within 24 hours

Frequently Asked Questions

The process train under assessment is: Incoming domestic sewage screening and flow equalisation → Anaerobic biological treatment in a composite tank → Secondary biological treatment with aeration and settled solids separation → Effluent filtration → Disinfection → Treated effluent collection and disposal or reuse → Digestion and dewatering of accumulated sludge → Storage and periodic collection of dewatered sludge.
Yes. Send us your daily and peak flow, influent quality, discharge or reuse target, operating hours and site constraints, and our engineers will reply with an initial process recommendation within 24 hours.

Planning a similar project?

Share your flow, influent quality and discharge target — our engineers respond within 24 hours.

AI Growth
Contact
Contact Us
Call Us
+86-181-0655-2851
Email Us Get a Quote Contact Us