Map the wastewater streams before choosing equipment
Light greywater is non-toilet wastewater from showers, bathroom basins and laundry, while toilets and kitchen grease traps form the separate heavy-blackwater stream described by Business360. Greywater Action notes that some commercial rainwater systems are called “greywater systems”; the actual source stream must be confirmed during the site survey.
Ask the site team to mark every inlet, existing diversion point, occupied operating period and abnormal flow event before selecting a treatment train. In a hotel, the survey should trace shower and basin drains, laundry discharges, toilet connections, kitchen outlets and the final drainage arrangement. This matters because a device selected for segregated light greywater may not be suitable once toilet wastewater enters the same collection system.
Use a hotel wastewater treatment route comparison to document whether each drain can be separated without disrupting occupied areas. The key procurement question is not whether the building produces greywater, but whether that stream can be captured reliably, kept separate from blackwater, and conveyed to a dedicated treatment process.
Record the operating period rather than assuming continuous flow. A hotel’s shower and laundry flows may be concentrated around specific hours, while a school or hospital may have a different daily pattern. Abnormal events—overflows, cleaning discharges, pump failures or storm-water entry—must be identified because they can change the required storage, equalisation and pretreatment provisions.
Choose segregated reuse or combined treatment
Greywater Action states that, at commercial scale, treating combined wastewater may be easier and more cost-effective than separating greywater, especially where the building already combines its drainage. To determine the most effective approach for a commercial greywater recycling system in Gambia, evaluate the feasibility of separating streams based on the following criteria.
| Decision field | Segregated light greywater | Combined wastewater |
|---|---|---|
| Source streams | Showers, bathroom basins and laundry, excluding toilets and kitchen grease traps | Greywater and blackwater collected through the building wastewater system |
| Collection condition | Each source must have a reliable, identifiable diversion point | Drainage is already combined |
| Treatment scope | Solids control and disinfection for the segregated stream | Broader biological and membrane treatment may be required |
| Installation effect | May require new pipework, tanks, pumping and controls | May reduce separation work but requires a broader treatment train |
| Preferred when | The property can capture the stream reliably and the reuse demand matches the available flow | Combined drainage already exists and separation would add disproportionate complexity |
Complete these fields before comparing prices: source streams, measured average and peak flows, reuse endpoint, available footprint, drainage configuration, treatment barriers, maintenance access and storage constraints. A supplier comparing package treatment and MBR for a hotel should receive the same completed data, otherwise the bids are not technically comparable.
For a new development, compare both plumbing arrangements before the drainage design is fixed. For an operating property, investigate retrofit disruption and whether the combined route allows reuse without extensive excavation. To review the decision in a hotel context, use the framework to compare package treatment and MBR for a hotel.
Match treatment barriers to the reuse endpoint

The commercial treatment sequence described by Greywater Action is collection in a temporary tank, filtration, disinfection, storage and pumping to the non-potable endpoint. Equipment selection should follow the source water and intended use rather than start with a membrane brand.
Where hair, lint, soap and particles are present, include granular filtration or an equivalent solids-removal barrier. Ion Exchange identifies UV, chlorine and biofiltration as possible additional disinfection steps. The endpoint must be defined: toilet flushing, managed irrigation and other non-potable applications should not be grouped together when they impose different exposure or operating requirements.
| Option | Applicable requirement | Catalogue parameters | Buyer must verify |
|---|---|---|---|
| UF water treatment system | Chemical-free removal of solids and bacteria | 2,000–40,000 L/h; 0.03 micron PVDF membranes; automatic backwash with air scour | Whether the source and pretreatment match the stated application, plus treated-water requirements for the intended endpoint |
| MBR membrane bioreactor | Combined wastewater requiring biological treatment and membrane filtration | 10–2,000 m³/day; filtration below 1 μm; 60% smaller footprint than conventional systems | Influent characteristics, biological loading, footprint basis, controls, sludge handling and acceptance tests |
The catalogue figures describe equipment capabilities, not guaranteed project performance. Require each bidder to demonstrate why its process fits the selected source stream and endpoint. An UF stage alone may be appropriate only if the upstream water quality and treatment objectives support that route; a combined wastewater system may require biological treatment before membrane separation.
Ask for the treatment sequence in writing: equalisation or temporary collection, solids removal, biological treatment where applicable, disinfection, storage and distribution. Also define what happens when one barrier is unavailable. A continuous reuse claim is credible only if the supplier explains storage turnover, bypass conditions and recovery from power interruptions.
Build a site-specific sizing and procurement brief
A comparable tender starts with measured site data and a common treatment-performance boundary. Obtain measured hourly flow, daily flow, peak factor, source-water analysis, storage requirement, reuse demand and available footprint from the property team or survey contractor. These are sizing inputs, not optional context for the supplier to estimate after selecting a package.
| Information request | Minimum entry required | Supplier response required |
|---|---|---|
| Source and flow | Stream diagram; measured hourly and daily flow; peak factor; operating and abnormal events | Design flow and the operating basis used |
| Water quality | Source-water analysis and relevant variability | Influent basis, pretreatment and treated-water target |
| Reuse | Non-potable endpoint, demand profile and required availability | Storage volume, pumping arrangement and overflow strategy |
| Equipment | Footprint, access, power and utility constraints | Treatment stages, disinfection method, controls and power demand |
| Operations | Maintenance access and available operating skill | Routine tasks, cleaning, backwashing, sludge removal and training |
Use published benchmarks as context, not as design guarantees. Business360 reports that toilet flushing represents 20%–40% of commercial water demand and that greywater can account for up to 75% of total domestic wastewater volume. The same source reports freshwater reductions of 30%–50% and average monthly savings of 24%–26% in hospitality case studies, but states that results depend on occupancy, reuse volume and operating conditions.
Require the tenderer to separate three commitments: treatment performance, available reuse volume and predicted freshwater reduction. Ask for the calculation method, baseline assumptions and metering arrangements. A supplier should not convert a published savings range into a guaranteed saving without demonstrating that the property’s measured flows and demand can sustain it.
A practical scope check can be developed through a package-plant procurement comparison: both bids should answer the same flow, treatment, storage, pumping, controls and maintenance questions before commercial terms are compared.
Verify safety, maintenance and local approval before purchase

The supplied research does not identify a specific Gambian permit, technical standard or reuse approval for this application, so approval criteria must be confirmed directly with the responsible Gambian authority or utility. Do not assume that a supplier’s overseas certification satisfies local requirements for discharge, reuse, construction or public-health protection.
Business360 describes multi-barrier filtration with chlorine or UV for non-potable reuse. Require the selected proposal to document its treatment barriers, their purpose and the treated-water acceptance criteria. The supplier should identify which barrier removes solids, which provides disinfection and what monitoring or testing demonstrates performance.
Include physical and operational acceptance requirements in the purchase specification: access for backwashing, membrane cleaning, chemical handling where applicable, sludge removal, spare-parts storage and operator training. Confirm access routes, lifting arrangements and valve positions before equipment delivery is scheduled.
Ask suppliers to explain how maintenance, power interruptions, odour control, overflow prevention and storage turnover affect uninterrupted operation. Include response actions, duty-standby arrangements, alarm notification and safe bypass or discharge provisions. For an MBR proposal, use the available submerged MBR design criteria to support technical review rather than relying on a general catalogue description.
Make final acceptance conditional on the locally confirmed reuse application, tested performance at agreed sampling points, operator handover and documented maintenance routines. If those items remain undefined, the commercial bid should remain a budgetary proposal rather than a guaranteed installation.
Frequently Asked Questions
How much should a commercial greywater recycling system cost in The Gambia?
No reliable Gambian quotation or project price is present in the supplied research, so a buyer should not budget from a generic per-unit figure. Request itemised quotations using the same measured flow, reuse endpoint, treatment target, footprint, storage, pumping and installation scope. Each bid should separate equipment, civil works, drainage alterations, power, commissioning, training, maintenance, consumables and permit-related verification. Also ask what price assumptions exclude, so the comparison reflects the actual property.
Should a Gambian hotel choose UF or MBR for greywater reuse?
Choose UF when the selected treatment route requires the stated solids and bacteria barrier and the source-water analysis supports that duty; the catalogue states 2,000–40,000 L/h, 0.03 micron PVDF membranes and automatic backwash with air scour. Consider MBR where combined wastewater requires biological treatment and membrane filtration; its catalogue states 10–2,000 m³/day and filtration below 1 μm. These specifications are selection screens, not site guarantees. Ask each supplier to demonstrate the complete treatment train and treated-water acceptance tests for the intended endpoint.
What flow and water-quality data should I request from a supplier?
Require the supplier to state its design flow and tie it to measured average flow, peak flow, peak factor, operating hours and abnormal events. Request source-water analysis, pretreatment assumptions, the treated-water target, storage basis and the method used to reconcile available flow with non-potable demand. If the data is unavailable, ask the property team or survey contractor to obtain it before bids are accepted; do not let each supplier substitute a different assumed occupancy profile.
Can treated greywater be used for toilet flushing and irrigation in Gambia?
Those are the non-potable applications identified in the supplied commercial guidance, but their acceptance in The Gambia must be confirmed with the responsible authority or utility. The supplied research does not specify a Gambian permit or reuse standard. Before purchase, define the exact application, treatment barriers, sampling points, monitoring requirements, public exposure controls and any restrictions on discharge or overflow. Approval should be recorded as a project condition rather than assumed from general international practice.
How do I compare bids when one supplier guarantees savings and another specifies treatment performance?
Ask both suppliers to state measurable guarantees separately: treated-water quality, available reuse flow, operating availability and freshwater reduction. Require the savings calculation, baseline period, occupancy assumption, metering boundaries and consequences of underperformance. Business360’s reported 30%–50% freshwater reductions and 24%–26% average monthly savings are contextual benchmarks, not guaranteed outcomes. Prefer a bid whose treatment guarantees can be tested at defined points and whose savings commitment is tied to verified site data and an agreed operating baseline.