Wastewater treatment expert: +86-181-0655-2851 Get Expert Consultation

300 m³/d lamella clarifier proposal for pharmaceutical wastewater

Proposed treatment for pharmaceutical wastewater based on a single lamella clarifier, subject to source, flow, loading and effluent-duty confirmation.

Project Background

The design basis is 300 m³/d for a pharmaceutical wastewater application with one lamella clarifier containing 24 inclined plates. Influent source, TSS, pH, flow profile, discharge route and required outlet quality remain unconfirmed. The proposed scope is suitable for preliminary engineering assessment only until wastewater characteristics and downstream treatment or discharge requirements are established.

Our Solution

The proposed solution uses a high-efficiency lamella clarifier to remove settleable solids after coarse screening, flow equalisation, coagulation and pH conditioning. Inclined plates provide compact clarification, while a downstream polishing and disinfection arrangement can be added according to the confirmed reuse or discharge duty. Settled sludge should be thickened and dewatered using a plate-and-frame filter press or another client-approved method, with residues stored and disposed of or reused under applicable requirements. A chemical dosing system is proposed where jar testing indicates a need for coagulant or pH control. Equipment material, coating, plate construction, hydraulic loading, detention time and solids handling will be finalised after the client supplies water-quality, flow and outlet data.

What We Asked First

Please confirm the wastewater source and provide TSS, pH and other relevant analyses. Also confirm operating hours, peak flow, discharge or reuse destination, required outlet limits, applicable standards and any chemical, sludge and containment requirements.

Proposed Process Train

  1. 1Influent characterisation and flow equalisation
  2. 2coarse screening
  3. 3coagulation and pH conditioning
  4. 4lamella sedimentation
  5. 5clarified water polishing
  6. 6disinfection if required
  7. 7sludge thickening and dewatering
  8. 8containerised sludge disposal or client-approved reuse

For Similar Projects

Prepare the wastewater source description, analytical report, flow records, effluent limits and sludge-disposal requirements so hydraulic loading, treatment stages and equipment materials can be finalised.

Ref. A-035. Client identity is withheld under our client-confidentiality policy. Capacity is shown as a capacity class (design value rounded up to the next 5 at its second significant digit).

How We Deliver

Projects of this type are delivered in the nine stages below. Installation, commissioning and other on-site stages follow each contract's scope. Every stage within our scope produces a written record that we keep on file.

  1. 1 Design basis confirmationAverage and peak flow, influent or gas data, discharge or reuse target Record producedDesign basis sheet
  2. 2 Process & mechanical designProcess calculations, equipment selection, layout and piping Record producedCalculation book, P&ID, general arrangement
  3. 3 Manufacturing & quality controlMaterial and in-process inspection of the main equipment Record producedMaterial & QC records
  4. 4 Factory acceptance test (FAT)Trial run against the design parameters before dispatch Record producedFAT record
  5. 5 Packing & dispatchPacked, marked and shipped against the equipment list Record producedPacking list
  6. 6 Installation or supervisionPer contract scope Record producedInstallation record
  7. 7 CommissioningStart-up, parameter tuning and interlocks Record producedCommissioning log
  8. 8 Performance verificationEffluent or emission checked against the design basis Record producedPerformance test record
  9. 9 Training, handover & after-salesOperator training, document handover, after-sales support Record producedO&M manual, training record

Planning a similar project? Start with these six parameters

  1. FlowDaily average and peak (m³/day and m³/h)
  2. Influent qualityCOD, BOD₅, TSS, pH and anything unusual
  3. Discharge targetThe standard you must meet, or the reuse purpose
  4. Operating hoursContinuous or batch; seasonal changes
  5. Site & civil scopeFootprint, power supply, who builds the tanks
  6. Project stageBudgeting, tender, or ready to order

Send your parameters — initial process recommendation within 24 hours

Frequently Asked Questions

This project is listed in the 300 m³/d capacity class: the design value rounded up to the next 5 at its second significant digit. Exact design values are not published.
The process train under assessment is: Influent characterisation and flow equalisation → coarse screening → coagulation and pH conditioning → lamella sedimentation → clarified water polishing → disinfection if required → sludge thickening and dewatering → containerised sludge disposal or client-approved reuse.
Yes. Send us your daily and peak flow, influent quality, discharge or reuse target, operating hours and site constraints, and our engineers will reply with an initial process recommendation within 24 hours.

Planning a similar project?

Share your flow, influent quality and discharge target — our engineers respond within 24 hours.

AI Growth
Contact
Contact Us
Call Us
+86-181-0655-2851
Email Us Get a Quote Contact Us