Wastewater treatment expert: +86-181-0655-2851 Get Expert Consultation
Equipment & Technology Guide

DAF Algae Removal from Tertiary Effluent: Clifton, Queensland 2026

For pond-based sewage plants whose lagoons bloom every warm season, a dissolved air flotation (DAF) unit with chemical pre-treatment on the tertiary effluent is the right route when algae arrive in episodic peaks and the downstream filters are the bottleneck: flotation lifts low-density algal flocs that gravity settling cannot capture reliably, and it can be sized for the bloom peak rather than the annual average. Our purchasing conclusion: award on a verified inlet characterisation, a bounded package scope and a performance test at commissioning, not on nominal capacity alone. What follows is engineering advice, not a tender condition or legal opinion.

On November 26, 2026, manufacturer Hydroflux Industrial announced on its news page (a vendor notice, not an owner or contractor statement) that it has been awarded the supply of two HyDAF systems for Clifton Sewage Treatment Plant, south of Toowoomba, Queensland, as part of a broader project being delivered by Pensar. The same page adds that the systems will remove unwanted algae from the treated wastewater, ease existing downstream filtration issues and process up to 12 L/s of tertiary effluent.

Why Pond Algae Pass Through Settling and Blind Tertiary Filters

A treatment pond is already a very large, slow gravity settler: what leaves it has had days to sink and has proved that it will not. Algal cells are small, close to the density of water and held apart by a surface charge, so a clarifier downstream receives solids with almost no settling velocity. Coagulation neutralises the charge and builds flocs, but algal flocs stay light: a settler then needs a heavier floc or a ballast, whereas DAF attaches micro-bubbles to the floc and floats it.

The load is also seasonal. In warm, sunny, calm weather cell numbers can climb sharply within days, and daytime photosynthesis raises pH, which shifts coagulant chemistry. A tertiary filter sized on the annual average then runs in short cycles, backwashes more often and risks turbidity breakthrough; if UV disinfection follows, particles shield the light. Treat the bloom peak, not the average, as the design case.

Matching the Process Route to Site Conditions

Inlet algal load: off-bloom and bloom seasons

Ask the supplier for the lowest flow and air rate at which the unit still performs, and its standby philosophy for the months when algae are scarce. For the design point, submit peak flow, peak algal solids and the warmest water temperature together: warm water holds less dissolved air, so it needs a higher recycle ratio or saturator pressure to deliver the same air. Request jar and bench flotation tests on real bloom samples across the seasonal pH range, not only on clear water.

Available footprint: retrofit inside an existing plant or new build

At an existing station the governing constraints are the free pad and the available head. If pond effluent cannot reach the flotation tank by gravity, pump it upstream of chemical injection, because pumping flocculated water shears the floc before bubbles attach. A pre-assembled package cuts site labour and suits retrofits, but confirm road transport limits and crane access; on a new build, reserve space for chemical storage, a float tank and maintenance access.

Downstream destination: tertiary filtration or direct discharge

When the outlet feeds filters, the turbidity leaving the DAF sets the filter run time, so agree an outlet target and ask how residual coagulant is controlled. When the water is discharged or reused, removing algal cells intact by coagulation and flotation is preferable to an algicide, which ruptures cells and releases their contents. Either way the floated scum is a concentrated algal sludge: remove it often and give it a defined route to sludge handling.

Tie-in: can the works be shut down?

If the plant must keep running, plan the connection around pond storage: lower the operating level, pre-fabricate spools, arrange temporary bypass pumping and tie in during low-flow windows. Whenever a proposal shows more than one train, ask for the operating philosophy and the guaranteed performance in each mode.

Chemical pre-treatment and the dissolved-air system

The usual sequence is coagulant injection, rapid mix, pH correction if needed, polymer addition, gentle floc formation and flotation; gentle mixing matters more than mixing power, because strong shear breaks light flocs. On the air side, a recycle pump pressurises clarified effluent in a saturator and releases it through nozzles as micro-bubbles. The technology list on the Hydroflux page names chemical pre-treatment, an integrated system, a non-clog recycle system and all-stainless fabrication in Australia or New Zealand: the vendor's own descriptions, not results measured at Clifton. They matter in practice, because a recycle stream carrying fine floc is a common cause of nozzle blockage and outdoor steel in permanent contact with coagulants is a corrosion risk. Ask for the nozzle-cleaning interval and the grade of stainless.

DAF or Lamella Settling: Which Fits Which Duty

The choice follows from the solids in the water, not from a preference for either technology: lamella clarifiers remain the economical answer when solids are mineral and settle readily, as our comparison of DAF and lamella clarification for metal fabrication pretreatment sets out in an industrial-wastewater context.

ConditionDAF with pre-treatmentLamella or gravity settler
Light algal flocs in a bloomPreferred: bubbles lift the flocNeeds a heavier floc or ballast
Mineral, settleable solidsSeldom the best fitUsually the simpler choice
Seasonal, intermittent runningQuick start and stopSlower to stabilise
Sludge producedConcentrated floatDilute underflow
Protection of filters downstreamStrong fit for algaeUncertain on algal solids

Sizing Logic: Inputs to Give and Outputs to Expect

Clifton is a useful reference for DAF algae removal from tertiary effluent, but only one duty figure is public: up to 12 L/s. Converted for convenience, 12 L/s × 86.4 = 1,036.8 m³/d, a unit conversion of the announced capacity rather than a design flow for any other site. For your own inquiry, we suggest sending:

  • Peak and average flow, with the daily and seasonal pattern.
  • Inlet quality in bloom and off-bloom: algal cell density or chlorophyll-a, suspended solids, turbidity, pH and alkalinity.
  • Water temperature range, because it sets air solubility.
  • Site constraints: available footprint, levels and head, indoor or outdoor, power supply.
  • Outlet targets and the downstream use: filtration, discharge or reuse.

In return, ask for a sized proposal that shows:

  • Surface loading rate and effective flotation area: effective area = design flow ÷ surface loading rate. Confirm whether the area is gross or net and whether recycle flow is added to the hydraulic load.
  • Recycle ratio, saturator pressure and air-to-solid ratio.
  • Flocculation time, number of stages and mixer type.
  • Scum removal method and expected float volume, to be confirmed by bench test.
  • Chemical types and doses from the tests, daily consumption and storage volume.
  • Installed power, dimensions and operating weight.
  • The performance guarantee and the test protocol behind it.

Any value the supplier has not measured on your water should read “to be confirmed by the vendor”, not an assumed figure.

Operating Conditions and Equipment Selection Reference

The products below are sold on this site and are shown as references for similar duties. They are not equipment selected for the Clifton project.

Process stepCondition it suitsReference product on this site
Core treatmentAlgal bloom peaks, light flocsDissolved air flotation (DAF) system
Chemical pre-treatmentCoagulant and polymer dosing, pH correctionAutomatic chemical dosing system
Alternative routeMineral or settleable solidsHigh-efficiency sedimentation tank (lamella)
Downstream protectionPolishing before discharge or reuseMulti-media filter

For the wider selection logic, see our guide on how to select a dissolved air flotation system for FOG and TSS, and for national context our page on wastewater treatment in Australia.

Interface Checklist When a Main Contractor Buys the Package

  • Scope split: what is on the skid and what is by others (civils, influent pumping, interconnecting piping, chemical supply).
  • Mechanical interfaces: tie-in points, flange standard and elevations at the pond outlet and filter inlet.
  • Power and controls: supply voltage, variable-speed drives, dosing paced from the flow signal, level and turbidity instruments, alarms to the plant SCADA and remote monitoring if the site is unmanned.
  • Inlet variability: the flow and water quality behind the guarantee, and the procedure when the bloom exceeds that envelope.
  • Installation: the shutdown window, bypass arrangements and tie-in sequence.
  • Commissioning: the performance test, who samples and tests, operator training, spares and service response.

RFQ Checklist Before You Request a Quote

  • Peak and average flow.
  • Water quality in bloom and off-bloom.
  • Water temperature range.
  • Available footprint, levels and head.
  • Outlet target and downstream use.
  • Power, controls and shutdown constraints.
  • Delivery period and the guarantees you expect.

Send these to us through the request a quote page; we will point out which sizing inputs still need a site survey or a bench test.

FAQ

What stage has the Clifton STP project reached?

As of the Hydroflux announcement of November 26, 2026, the public stage is a supply award to Hydroflux. Delivery, installation, commissioning and operation are subject to follow-up information from the owner, Pensar or Hydroflux.

Why choose flotation rather than settling to remove algae?

Algal cells are close to the density of water and barely settle, even after coagulation. DAF attaches micro-bubbles to the flocs so they rise, which suits low-density, seasonal solids and protects downstream filters.

What should a buyer prepare before requesting a DAF quotation?

Peak and average flow, water quality in bloom and off-bloom, water temperature, site levels and head, outlet target and downstream use. A real bloom sample for bench testing is more valuable than any assumed figure.

What did the Hydroflux announcement not disclose?

Equipment models and unit dimensions, how the two systems are configured, recycle ratio and saturator pressure, the chemicals and their doses, measured removal rates, contract value, delivery and commissioning dates, the owner's name and the scope of the project Pensar is delivering. These remain to be confirmed by the owner or the vendor.

References

  1. Hydroflux Awarded HyDAF Systems for Algae Removal at Clifton STP

Related Articles

DAF vs. Lamella for Fabricated Metals Sewer Pretreatment
Nov 21, 2026

DAF vs. Lamella for Fabricated Metals Sewer Pretreatment

Use permit limits, wastewater properties and sizing data to choose DAF or lamella clarification for…

How to Select a Dissolved Air Flotation System for FOG and TSS
Nov 17, 2026

How to Select a Dissolved Air Flotation System for FOG and TSS

Plant-engineer checklist for selecting dissolved air flotation when FOG or light TSS dominate, vers…

AI Growth
Contact
Contact Us
Call Us
+86-181-0655-2851
Email Us Get a Quote Contact Us