Proposed MBR treatment for an unidentified soil-waste stream, subject to source clarification, water analysis and confirmation of reuse requirements.
Project Background
The client-supplied design basis is 100 m³/d with an unspecified soil-waste source and no water analysis or confirmed reuse destination. The design must also establish daily flow variation, operating hours, peak conditions, pollutants, site constraints and whether complete treatment, sludge handling or only membrane equipment is required.
Our Solution
We propose screening, flow equalisation and source-appropriate pretreatment before an MBR biological reactor. The MBR stage provides mixed-liquor solids separation without a conventional clarifier, while chlorine dioxide can disinfect the treated water where validated for the application. A dedicated sludge line will condition and dewater residual solids with a plate-and-frame filter press; the final destination must be based on testing and local requirements. Equipment may also require DAF or lamella clarification if oil, solids or settleable material is significant. MBR suitability, pretreatment, disinfection, storage and sludge reuse remain subject to source identification, water analysis and the intended reuse or discharge standard.
What We Asked First
Please confirm the waste source, intended project use, flow variation and operating schedule, pH, COD, BOD₅, TSS, ammonia, TN, TP, oil, salinity and special pollutants, reuse or discharge requirements, site details, electrical supply and delivery location.
Proposed Process Train
- 1Source segregation and flow equalisation
- 2Screening and grit removal
- 3Biological treatment with MBR
- 4Chlorine dioxide disinfection
- 5Treated-water storage or reuse
- 6Sludge conditioning and plate-and-frame dewatering
- 7Dewatered sludge collection for an approved use or disposal
For Similar Projects
Prepare the source description, complete water analysis, flow and load record, reuse or discharge criteria, site drawings, available utilities and required supply scope before selecting equipment or confirming the process design.
Ref. A-032. Client identity is withheld under our client-confidentiality policy. Capacity is shown as a capacity class (design value rounded up to the next 5 at its second significant digit).