Shanghai QILEE Environmental Equipment Co., Ltd. announced on 17 November 2026 that its skid-mounted PTFE membrane ammonia removal system had been commissioned and operationally validated at a major chemical manufacturer in Java, Indonesia, with a treatment capacity of 120 cubic meters per day (120 m³/d). FinancialContent
The installation treats high-strength industrial wastewater and is intended to reduce ammonia nitrogen to discharge levels of 15 mg/L or less while recovering ammonium sulfate solution for sale as liquid fertilizer to local agricultural distributors. FinancialContent
What happened
Before commissioning the membrane system, the chemical plant used a conventional air-stripping tower that the supplier said created persistent bottlenecks, inconsistent effluent quality, high chemical and energy expenditure, a substantial physical footprint and uncontrolled atmospheric ammonia slip. FinancialContent
After on-site pilot testing and technical evaluations, the manufacturer selected QILEE’s proprietary polytetrafluoroethylene hollow-fiber membrane ammonia recovery package. The company said the Java installation is its primary Indonesian reference case for PTFE membrane ammonia stripping and recovery. FinancialContent
The reported treatment train has five continuous stages: raw wastewater pretreatment, automated pH adjustment, PTFE hollow-fiber membrane gas-liquid contacting, closed-loop sulfuric acid absorbent circulation and final ammonium sulfate recovery. FinancialContent
Following assembly, commissioning and operator training by QILEE’s technical engineering team, the plant entered continuous commercial operation. Performance audits reported effluent ammonia nitrogen concentrations of no more than 15 mg/L from influent levels of 1,800–2,500 mg/L, with ammonia removal efficiency exceeding 99 percent. FinancialContent
QILEE reported that the enclosed membrane design eliminated fugitive ammonia emissions associated with the former stripping tower, while the skid reduced the system footprint by more than 60 percent compared with the decommissioned installation. Plant management reported negligible downtime, straightforward maintenance and lower operating expenditure through reduced heat and chemical consumption. FinancialContent
Specification Read
The reported scale is 120 m³/day, equivalent to 0.12 MLD. The source did not report population-equivalent capacity, so that basis cannot be calculated from the supplied information. FinancialContent
This project addresses the tertiary ammonia-control and resource-recovery end of a chemical-plant treatment train: pretreatment and pH adjustment precede hydrophobic PTFE membrane gas-liquid contacting, sulfuric acid absorption and ammonium sulfate recovery. The source does not provide the upstream screening, primary or biological-treatment configuration, nor project-specific biological loading data, so those stages cannot be specified from this event. FinancialContent
If your chemical plant has a wastewater flow of 120 m³/day, ammonia nitrogen of 1,800–2,500 mg/L, a discharge target of 15 mg/L or less and pressure to contain odor while recovering a saleable product, this project shows a modular PTFE membrane approach that reported more than 99 percent ammonia removal and a footprint reduction exceeding 60 percent. FinancialContent
For broader plant-layout context, the Mbr Membrane Systems product hub covers membrane treatment options, while the Chemical industry page provides a plant-specific reference point. QILEE offered turnkey execution covering process simulation, pilot verification, custom equipment manufacturing, international logistics, on-site commissioning and lifecycle technical service. FinancialContent
FAQ
What treatment flow and ammonia performance did the project achieve?
The installation processes 120 m³/day of high-strength industrial wastewater. Performance audits reported effluent ammonia nitrogen of no more than 15 mg/L from influent levels of 1,800–2,500 mg/L, representing ammonia removal efficiency exceeding 99 percent. FinancialContent
What operating-cost benefits were reported?
Plant management reported lower operating expenditure through minimized heat inputs and lower chemical consumption relative to the previous stripping tower. The source did not provide a project price, operating-cost value or contractual savings figure, so those figures cannot be compared from the supplied information. FinancialContent
How was the ammonia recovered into a saleable product?
In the reported five-stage train, pH adjustment enables ammonium to become free ammonia, PTFE hollow-fiber membranes transfer the gas to a circulating sulfuric acid solution, and the final stage recovers ammonium sulfate. The captured solution is sold directly to local agricultural distributors as liquid fertilizer. FinancialContent
What should a buyer evaluate when selecting a supplier for this treatment duty?
QILEE’s stated scope included process simulation, pilot verification, custom equipment manufacturing, logistics, commissioning and lifecycle service. Buyers should also request project-specific performance evidence; the reported audit found effluent ammonia nitrogen of no more than 15 mg/L and ammonia removal efficiency exceeding 99 percent, but the source did not disclose the audit method or testing protocol. FinancialContent