Arauco's Sucuriú effluent plant: the direct answer
Arauco has selected Veolia to design and implement the industrial effluent treatment plant for its Sucuriú pulp mill in Inocência, Mato Grosso do Sul, Brazil, Veolia announced on November 2, 2026. The plant will treat 10,600 m³ of wastewater per hour, about 254,000 m³ a day, with a biofilm activated sludge process that combines a moving bed bioreactor with activated sludge, plus belt presses for sludge dewatering. The US$4.6 billion mill is designed for 3.5 million tonnes of short-fiber pulp a year and is on track to start by late 2027. For suppliers, the remaining work is to define and price the duties around that line: preparation, biology support, sludge and chemicals.
This guide sets out what the announcement contains, what kraft pulp mill effluent typically holds, why a biofilm process was chosen for biology, how belt and plate presses differ for sludge, and how to size and budget equipment for a mill-scale effluent plant.
What Veolia and Arauco announced on November 2, 2026
Veolia's press release describes the Sucuriú Project as Arauco's first pulp mill in Brazil and as planned to be the world's largest industrial facility built in a single phase. The US$4.6 billion plant will produce 3.5 million tonnes of short-fiber pulp a year. Veolia will design and implement the effluent treatment line with a capacity of 10,600 cubic meters of wastewater per hour and will draw on more than 50 years of experience in pulp and paper water treatment. Trade publications including Wastewater Digest and METissue reported the award on November 2 and 3.
Leonardo Crociati, Executive Manager of Implementation for the Sucuriú Project at Arauco, called the project "the largest project built in a single phase in the world" and a historic milestone for the company. He added that an undertaking of this scale demands partners who share a commitment to sustainability. Anne Le Guennec, CEO of Veolia's water technology activities, said that securing water resources and protecting local ecosystems have become essential to business continuity, and linked the work to Veolia's GreenUp strategic program.
Veolia compares the organic load the line will treat with that generated by 3 million inhabitants. Multiplied out, 10,600 m³/h is 254,400 m³ a day, or about 67 million US gallons, a flow on the scale of a large city's treatment works. The release does not give influent loads, effluent limits, the receiving water body or a plant layout, and it does not say which parts of the scope are open to other suppliers. Those gaps are where the guidance below begins.
What kraft pulp mill effluent contains

The announcement does not describe the mill process. Short-fiber pulp in Brazil is normally bleached eucalyptus kraft pulp, and a mill of that type produces several effluents with different behavior, which are usually combined, equalized and treated together.
- Wood preparation. Debarking and chipping release bark fines and tannins that add color and suspended solids.
- Cooking and brown stock washing. Spills and losses of black liquor carry lignin fragments, organic acids, resin acids and fatty acids that are slowly biodegradable and can inhibit biology in concentration.
- Bleaching. Filtrates from chlorine dioxide bleaching add color, chlorate and small amounts of adsorbable organic halides.
- Condensates and causticizing residues. Evaporator condensates carry methanol and reduced sulfur compounds, while green liquor dregs add inert solids.
- Utility streams. Boiler blowdown, cooling water and water treatment residuals arrive in large volume with little organic load.
Three traits shape the design. Color and chemical oxygen demand run high in relation to biochemical oxygen demand, because much of the lignin-derived material resists biological attack. Nutrients are low relative to the organic load, so nitrogen and phosphorus must be dosed to sustain the biomass. Temperature is high, often above the range at which mesophilic microorganisms work best, and batch losses of black liquor or soap can arrive as a toxic shock. Equalization, cooling and nutrient dosing therefore come before biology, and the biology must tolerate swings in load.
Water reuse changes the picture a second time. A mill that returns treated effluent to the process instead of drawing fresh water concentrates salts and non-biodegradable organics with every cycle, so the reuse polish must be sized on the contaminants that accumulate, not on the flow alone.
Why a moving bed bioreactor with activated sludge
Veolia's biofilm activated sludge process combines a moving bed bioreactor stage, where microorganisms grow as attached biofilm on plastic carrier media, with an activated sludge stage that follows. Combining the two raises the biomass held per basin volume without adding basin volume, and the biofilm shields part of the biomass from shock loads, so the stage recovers quickly after an upset. Veolia states that the arrangement maximizes capacity in a compact footprint.
Against the alternatives, that combination sits in the middle on most criteria. Aerated lagoons are simple and forgiving but need large areas and long retention times. Conventional activated sludge needs less land than lagoons but more than a biofilm system for the same load. Membrane bioreactors produce the clearest effluent and suit water reuse, but at 10,600 m³/h the membrane area and replacement cost become substantial. Our feasibility guide to IFAS for pulp and paper wastewater covers the same carrier-plus-activated-sludge arrangement from a retrofit angle.
| Process | Footprint | Effluent solids | Main operating cost | Best fit |
|---|---|---|---|---|
| Aerated lagoon | Large | Moderate | Aeration power, land | Mills with cheap land and steady load |
| Activated sludge | Medium | Depends on clarifier | Aeration power, nutrients | Predictable load with room for basins |
| Moving bed plus activated sludge | Small to medium | Depends on clarifier | Aeration power, nutrients, carriers | High load with frequent shocks or retrofits |
| Membrane bioreactor | Smallest | Very low | Membrane replacement, fouling control | Reuse-grade effluent at moderate flow |
A membrane bioreactor package from 10 to 2,000 m³/day therefore fits the mill's smaller reuse streams, such as polished effluent returned as process water, rather than the main line. Upstream of biology, a dissolved air flotation system in the 4–300 m³/h range serves segregated streams where fibers, pitch or oils must be recovered, while the main flow is usually handled by primary clarifiers sized for the full volume.
Biology leaves most of the color in place. Where a license sets limits on color or adsorbable organic halides that biological treatment cannot meet, mills add a tertiary stage such as coagulation, ozonation or advanced oxidation. Each of those options produces a chemical sludge of its own, which adds a further dewatering duty and a further line in the operating budget.
Sludge: belt press or filter press

Veolia's scope includes proprietary belt presses. A belt press runs continuously: sludge conditioned with polymer is drained between two moving belts and squeezed through a series of rollers. It handles large flows with modest staffing, but the cake leaves with more water than a plate press produces. A plate and frame filter press works in batches, pumping sludge into framed chambers until they fill with cake, and it reaches higher cake solids, especially with membrane squeeze plates.
That difference decides disposal cost. Sludge sent to landfill is charged by weight, so every extra point of cake dryness gained in pressing reduces the bill for transport and tipping. Primary sludge, rich in fiber and bark, dewaters readily and holds fuel value if the mill's boilers are licensed to burn it. Biological sludge is harder to dewater and more often goes to land application or landfill after stabilization. Brazil's National Solid Waste Policy, Law 12,305 of 2010, requires each route to rest on waste characterization and licensing, and a drier cake widens the routes a mill can defend.
HydropureWater plate and frame filter presses cover 1–500 m² of filtration area with plate sizes from 450 to 1,500 mm, feed pressures up to 0.6 MPa and optional membrane squeeze plates. For a mill of Sucuriú's scale they suit streams that need a drier cake than a belt line delivers, such as DAF float, chemical sludge from color removal or the smaller flows around the main biological plant.
Sizing and budget logic around a mill-scale effluent plant
With the main line awarded, a supplier's task is to define the duties that sit around it. Six inputs fix any of them: average and peak flow, the load of each pollutant, the limit to be met, the temperature and pH range, the hours per day the stream arrives, and the space and power available. In Brazil the limits come from CONAMA Resolution 430 of 2011 at federal level together with any stricter conditions written into the mill's installation and operating licenses, which the supplier should read rather than infer.
Translating Veolia's comparison gives a first sense of scale but no more. The release does not say whether the 3 million inhabitant figure refers to BOD or COD. If it refers to BOD and a per-capita load of 54–60 g a day is applied, the load is roughly 160–180 tonnes of BOD a day. Treat that as a screening figure only, because the mill's own mass balance, not a public comparison, is the design basis.
Budgets at this scale split into lines that respond to different variables:
- Civil basins and earthworks. Equalization, biological basins and clarifiers form the largest share at a greenfield site and scale with volume, which follows load and retention time more than flow alone.
- Aeration and mixing. Blowers, diffusers and mixers scale with oxygen demand. Each kilogram of BOD removed needs roughly a kilogram of oxygen, and nitrification, where the license requires it, adds about 4.6 kilograms of oxygen per kilogram of ammonia nitrogen.
- Carriers and media. Carrier volume follows the attached-growth fraction chosen to absorb shock loads.
- Chemical systems. Nutrient, polymer, antifoam and pH dosing skids scale with dose rates, which follow the nutrient gap in the effluent and the sludge volume.
- Sludge handling. Thickeners, presses and conveyors scale with dry solids and with the dryness the disposal route demands.
- Instrumentation and start-up. Continuous measurement, a control system and several weeks of biological acclimation belong in the budget from the start.
Operating cost is dominated by aeration power, nutrients and polymer, and sludge transport. Many Brazilian mills generate their own power from biomass, which lowers the weight of electricity but not the value of efficient blowers. A greenfield site away from an industrial centre adds two more variables: construction power and skilled labor may be limited, which favors modular skids assembled off site and control systems that support remote monitoring.
| Effluent flow | Usual layout | Supplier openings |
|---|---|---|
| Below 1,000 m³/h | Single-train biology, one clarifier, one press | Package plants, DAF, chemical skids |
| 1,000–5,000 m³/h | Two trains, separate thickeners | Sludge handling, polishing for reuse, instruments |
| Above 5,000 m³/h, as at Sucuriú | Multiple trains, several clarifiers, dedicated dewatering | Segregated-stream DAF, specialty sludge, carriers and spares |
To quote one of these packages, send the stream's flow and hours, the lab profile, the license limit and the site conditions. With those in hand, request a quotation through /request-quote.html and the scope can be drawn around a defined duty. More wastewater projects from the region are listed on our Brazil location page.
Frequently Asked Questions
What does 10,600 m³ per hour mean for equipment sizing?
It is the capacity of the main effluent line, equal to 254,400 m³ a day. Equipment around that line is not sized from the total. A DAF unit, a filter press or a chemical skid is sized from its own stream, so the first step is to obtain the flow and load of the stream in question and the hours it runs, then apply a peaking factor for batch releases.
Why choose a moving bed bioreactor with activated sludge instead of an MBR?
The biofilm and activated sludge combination treats a high and variable load in a compact basin at moderate operating cost, and it avoids membrane replacement at a flow where membrane area would be very large. An MBR gives clearer effluent and makes sense for smaller streams inside the mill where treated water is recovered for reuse.
Is a filter press better than a belt press for pulp mill sludge?
Neither is better in every case. A belt press suits large, steady sludge volumes with continuous operation, which is why it sits in the Sucuriú scope. A plate and frame filter press gives a drier cake in batches and lowers transport and tipping cost, so it suits smaller streams or mills whose disposal route depends on dryness.
What should a supplier send to be considered for a project like Sucuriú?
Send a scope statement for one defined duty, the capacity range offered with its design basis, materials and standards, reference installations on similar streams, and a clear boundary showing what the package excludes. Suppliers who state what data they need from the mill, such as the lab profile and license limit, are easier to place inside a larger engineering schedule.