Match the Treatment Train to the Wastewater
A high-COD industrial wastewater treatment system in Mali should normally be selected as a treatment train, not as one stand-alone machine. Food-processing streams can contain thousands of milligrams per liter of COD, and in some cases tens of thousands. Use DAF to remove floatables, oil, grease and suspended solids when those are present; select biological treatment for soluble biodegradable organics; and evaluate anaerobic digestion where its feed suitability and biogas-use conditions justify it. A published 1,500 L/day reactor study achieved 91.7% COD removal at 5,000 mg/L COD under its designed condition, but this is not a Mali-site guarantee. Final selection requires measured flow, COD, solids, pH, temperature, discharge route and permit criteria.
COD measures the dissolved oxygen required to chemically oxidize organic material, while BOD measures the oxygen required for microorganisms to break down biodegradable organics. The relationship between COD and BOD must be established for the actual wastewater rather than assumed. Hach also recommends influent and effluent sampling at defined points to measure oxygen demand and demonstrate performance (S4).
Separate the wastewater into floatables, suspended and colloidal solids, soluble biodegradable COD, and contaminants that could inhibit biological treatment. Food-industry streams may contain nitrogenous organics, organic carbon, suspended solids, dissolved solids and inorganics, and their composition can vary substantially between applications and production conditions (S1).
| Discharge route or influent problem | Governing rule or process option | What data settles it |
|---|---|---|
| Oil, grease, floatables or significant suspended solids | Include industrial effluent pretreatment; an industrial DAF pretreatment system is appropriate when those fractions must be removed before biological treatment. | Representative oil-and-grease, suspended-solids, floatables and COD samples from each production and washdown stream. |
| High soluble biodegradable COD after pretreatment | Consider an MBR membrane bioreactor system, with aerobic load and solids separation defined against the permit. | Flow, soluble and total COD, BOD, ammonia, pH, temperature, toxicity, aeration demand and required effluent quality. |
| Sustained biodegradable organic loading with a practical biogas use | Evaluate anaerobic digestion as a route for recovering energy and concentrating nutrients, subject to feed suitability and local gas-use conditions (S1). | Organic-load profile, alkalinity, temperature, pH, nutrient balance, sulfate and toxicity assessment, plus a defined use for harvested gas. |
| Discharge to a receiving water or reuse destination | Do not select final treatment from a generic reuse or discharge label; obtain the applicable route-specific criteria first. | Written discharge route, receiving-water context, reuse specification, sampling points and applicable Mali permit conditions. |
Use the broader industrial wastewater equipment selection guide to distinguish unit-operation functions before preparing supplier quotations.
Compare DAF, MBR and Anaerobic Routes
The choice of route depends on contaminant properties and site constraints rather than a single reactor headline. DAF is principally a solids- and float-removal step; it does not by itself establish that soluble biodegradable COD has been treated. MBR combines biological treatment with membrane solids separation, while anaerobic digestion requires a suitable feed and a credible route for using the recovered gas.
The available reactor evidence has a narrow scope. A three-phase fluidized bed reactor was designed for 1,500 L/day of high-strength wastewater containing 5,000 mg/L COD and 230 mg/L ammonia, with an 8-hour hydraulic residence time. Under that study’s designed condition, it achieved 91.7% COD removal and 56.7% ammonia removal, with low effluent suspended solids (S2). These results apply to the cited study condition; they are not guaranteed performance for an unspecified Mali plant or for every high-COD stream.
For DAF, verify that recovered float and sludge volumes, chemical demand and waste destinations are acceptable. For MBR, require the supplier to explain membrane design, aeration, cleaning, replacement assumptions and how the selected solids-retention basis responds to the actual load. For anaerobic digestion, require evidence that the feed is sufficiently biodegradable, that nutrients and alkalinity support the process, and that methane or other usable gas has a practical destination.
The IFAS design guide for food-processing wastewater can help frame biological loading and solids-retention questions. The DAF, MBR and packaged-plant comparison for industrial effluent provides a useful route-comparison structure, but the final selection still depends on the Mali site data.
Build the Design Basis Before Requesting a Quote

A defensible quote requires measured stream data and a stated sizing basis. Ask for a representative COD dataset covering production, washdown and clean-in-place streams, including seasonal and batch variation. A single sample or only the average daily flow will not establish the treatment capacity.
Request flow data across the hydraulic profile, together with total and soluble COD, BOD, suspended solids, oil and grease, pH, temperature, ammonia and toxicity information. Confirm whether the stream is batch-continuous, whether flow is diverted during cleaning, and whether equalization is required. These inputs also determine whether pretreatment should precede biological treatment and whether the anaerobic route is realistic.
Identify the discharge route, receiving-water context, reuse destination and applicable Mali permit criteria. Name the party responsible for confirming them with the relevant authority. The available information does not establish a Mali-specific discharge limit or approving authority, so a supplier’s general compliance statement is not a substitute for a project-specific permit check.
Document the available footprint, electrical power, compressed air, service water, chemicals, drainage and operator coverage. Also define the sludge or solids destination. Pretreatment transfers captured contaminants into a concentrated stream that still requires handling, and this responsibility must appear in the process and commercial scope (S1).
Use the DAF, MBR and packaged-plant comparison for industrial effluent as a route-screening reference. When comparing municipal-style packaged arrangements, apply the same discipline required for an industrial project: obtain the stream data, performance boundary and utility requirements rather than relying on a generic package description.
Turn the Selection into a Supplier RFQ
State the selected train as pretreatment, biological treatment, solids handling and any disinfection or reuse stage, with the technical reason for every stage. Require each bidder to state design flow, design COD, hydraulic-retention basis, oxygen or air demand, sludge yield and utility consumption. An RFQ that omits these fields cannot support an apples-to-apples comparison.
| Quote line item | Technical scope to specify | Red flags to check before signing |
|---|---|---|
| Influent design basis | Design flow, total and soluble COD, BOD, suspended solids, oil and grease, ammonia, pH, temperature, toxicity and operating variation. | A quotation based only on average flow, one COD sample or an unnamed “similar” industry. |
| Pretreatment | DAF duty, chemical dosing if required, recovered-float characteristics, sludge yield, controls and cleaning access. | No stated design flow, no chemical requirement or no destination for recovered solids. |
| Biological treatment | Process selection, hydraulic-retention and solids-retention basis, oxygen or air supply, ammonia assumptions and solids separation. | Published performance from another reactor is presented as a guarantee without matching influent conditions. |
| Solids handling and disposal | Sludge or float removal, storage, dewatering or transport interface, destination and responsible operator. | Removal and disposal are excluded without identifying who will perform them. |
| Controls and utilities | Power load, compressed air, water, chemicals, alarms, data logging, control narratives and utility connection points. | Utility consumption is excluded or shown without connection details and operating assumptions. |
| Delivery and handover | Shipping to Mali, installation, commissioning, training, manuals, critical spares, support and performance testing. | Installation, customs, rigging, foundations, training or regulatory support are listed only as vague exclusions. |
| Performance acceptance | Sample point, parameter, test method, influent condition, loading condition, operating period and required result. | A generic removal percentage with no sample point, test method or documented influent condition. |
Separate equipment, shipping, installation, commissioning, spares, controls and consumables in the commercial schedule. List all exclusions explicitly, including civil works, power supply, chemicals, operator training, sludge removal and regulatory approvals. Use the industrial wastewater equipment selection guide to check that the technical and commercial scopes align.
Confirm Performance, Handover and Local Delivery

Make acceptance testing conditional on documented influent and operating conditions. Use COD and BOD or other required discharge measurements to verify performance, while obtaining the applicable Mali permit values and test methods from the designated local authority. The available information does not identify Mali-specific thresholds, so no universal effluent value should be inserted into the contract.
Define sample points before supplier evaluation. Hach advises measuring COD or BOD in the influent before mechanical screening and in the effluent at the discharge point, because sampling location affects the meaning of the result (S4). The acceptance plan should also state who takes samples, which analytical method applies, how operating conditions are recorded and what happens if an influent deviation invalidates a test.
Include site acceptance testing, operator training, control-system demonstrations, maintenance manuals, critical spares and remote or local technical support in the handover schedule. Require a documented performance test tied to the selected site’s influent conditions rather than copying a result from another wastewater stream (S2).
Clarify whether the offer is EXW, FOB, CIF, delivered or delivered and installed. Assign responsibility for import, customs clearance, insurance, delivery, unloading, rigging, foundations, utilities and commissioning. For Mali delivery, request realistic lead times, packing details, shipment terms and a named local support arrangement before accepting the commercial schedule.
Frequently Asked Questions
What flow and COD measurements are needed before choosing treatment capacity?
Obtain a representative flow profile and paired influent and effluent COD results covering production, washdown, clean-in-place, seasonal and batch conditions. For process design, also request total and soluble COD, suspended solids, oil and grease, pH, temperature, ammonia and toxicity data. Hach identifies influent sampling before mechanical screening and effluent sampling at the discharge point as the appropriate locations for compliance measurements (S4).
When is DAF pretreatment rather than the complete treatment solution?
Use DAF when oil, grease, floatables, suspended solids or colloidal material must be removed before biological treatment. It is pretreatment rather than complete treatment when soluble biodegradable COD remains. Ask the supplier to quantify the captured contaminants and show how the resulting float or sludge will be removed, stored and disposed of.
What information is required for an apples-to-apples supplier quotation?
Request the design flow, design COD, process and sizing basis, hydraulic-retention basis, oxygen or air demand, sludge yield, utility consumption, controls scope, exclusions, delivery terms and acceptance-test protocol. Require separate prices for equipment, shipping, installation, commissioning, spares, controls and consumables. A price without the stated design basis is not comparable.
Does a supplier compliance statement establish compliance with Mali discharge requirements?
No. Require the project-specific discharge route, receiving-water or reuse conditions, applicable permit criteria, sample points and test methods. Name the party responsible for confirming these requirements with the relevant Mali authority and including them in the contract. The available information does not establish a Mali-specific limit or approving authority, so the supplier’s generic statement should not be treated as a permit.